AUXILIARY: PVC VINITEX

Vinitex Desagüe + Paragravillas
Vinitex Gárgola
Vinitex Esquina
Vinitex Rincón
Vinitex Colaminado - Plancha
Vinitex Colaminado - Tira
Barra de Terminación
Vinitex Adhesivo soporte
Vinitex Líquido
Rodillo de Presión en Silicona
  AUXILIARY: TPO TEXSALON
   
Texsalón Desagüe
Texsalón Gárgola
Texsalón Terminación
Texsalón Esquina - Rincón
Texsalón Colaminado - Plancha
Texsalón Barra de terminación
Texsalón Refuerzo
Sellador de Borde Transparente
Texsalón Adhesivo de Soporte
Rodillo de Presión en Silicona
  AUXILIARY: EPDM SURE-SEAL
   
Sure-Seal Pressure-Sensitive     SecurTAPE
Sure-Seal HP-250 Primer
Sure-Seal Pressure-Sensitive     Elastoform Flashing
Sure-Seal Pressure-Sensitive     Russ
Wearhered Membrane Cleaner
Sure-Seal Splicing Cement
In Seam Sealant 1124
Sure-Seal Lap Sealant
Sure-Seal Flashing
Sure-Seal Russ
EPDM Desagüe - Paragravillas
Sure-Seal Bonding Adhesive
    90-8-30A

EPDM Barra de Terminación
Water Cutoff Mastic
Pourable Sealer
Rodillo de Terminación Metálico
Rodillo Aplicación Adhesivo
Mango Aplicación Adhesivo
Sure-Seal MP 1.14
AUXILIARY PRODUCTS

Sure-Seal cinta rápida
Sure-Seal Pressure-Sensitive SecurTAPE

Sure-Seal imprimación
Sure-Seal HP-250 Primer


Sure-Seal terminación
Sure-Seal Pressure-Sensitive Elastoform Flashing


Sure-Seal refuerzo
Sure-Seal Pressure-Sensitive Russ


Sure-Seal desagüe
Sure-Seal Desagüe + Paragravillas DD110 mm


Sure-Seal barra terminación
Sure-Seal EPDM Barra de terminación


Sure-Seal cutoff mastic
Water Cutoff Mastic



Sure-Seal rodillo presión
Rodillo de Presión Metálico
Sure-Seal MP 1.52
 
(PDF) Download Print version
 
   
 
GENERAL

Sure-Seal 60-mil thick (1.52 mm) roofing membranes are polyester reinforced Ethylene Propylene Diene Terpolymer EPDM based elastomeric homogenous roofcoverings which may be used for new single-ply roof construction and reroofing applications.

Membranes are available in widths up to 10' (3 m) and lengths up to 200' (61 m). Custom dimensions are also available. Fire Retardant (FR) membranes are specially formulated to inhibit spread of flame and meet or exceed code body testing criteria for fire retardant roofing membranes.

   
 
CAUTIONS AND WARNINGS

• Use proper stacking procedures to ensure sufficient stability of the materials.
• Exercise caution when walking on wet membrane. Membranes are slippery when wet.

   
 
INSTALLATION

For Mechanically-Fastened Roofing Systems: Insulation is mechanically attached to roof deck and membrane is secured with seam fastening plates and fasteners. Splicing Cement and In-Seam Sealant. are applied to the splice area and Lap Sealant is used on the splice edge. As an alternate, HP-250 or LV-600 Primer and SecurTAPE. may be used for splicing.

For Design A, Fully-Adhered Roofing System: Insulation is mechanically attached to the roof deck. The substrate and membrane are coated with Sure-Seal Bonding Adhesive. The membrane is then rolled into position and brushed down. Splicing Cement and In-Seam Sealant. are applied to the splice area and Lap Sealant is used on the splice edge. As an alternate, HP-250 or Primer and SecurTAPE may be used for splicing.

 
 
PROPERTIES AND CHARACTERISTICS
 
 

PHYSICAL PROPERTY

TEST METHOD
ASTM SPEC (Pass)

1.52 STANDARD

Tolerance on Nominal Thickness, %

ASTM D 751

±10

±10

Thickness Over Scrim, min, in. (mm)

ASTM D 4637
Annex

0.015 (0.381)
0.015 (0.381)

0.020 (0.508)

Weight, 1bm/ft 2 (kg/m2) 1.14

 

...

0.24 (1.7)

Breaking Strength, min, lbf (N)

ASTM D 751
Grab Metod

90 (400)

180 (800)

Elongation, Ultimate, min, %

ASTM D 412
Die C

250**

480**

Tearing Strength, min, lbf (N)

ASTM D 751
B Tongue Tear

10 (45)

30(132)

Brittleness Point, max, deg. F (deg. C)*    

ASTM D 2137

-49 (-45)

-60 (-51)

Resistance to Heat Aging*
Properties after 4 weeks @ 116 ºC
Tensile Strength, min, psi (MPa)
Elongation, Ultimate, min, %
Tear Strength, min, lbf/in (kN/m)
Linear Dimensional Change, max, %

ASTM D 573

ASTM D 412
ASTM D 412
ASTM D 624
ASTM D 1204



80 (355)
200**

±10



200(800)
250**

-0.7

Ozone Resistance*
Condition after exposure to 100 pphm
Ozone in air for 168 hours @ 40 ºC
Specimen is at 50% strain

ASTM D 1149

No Cracks

No Cracks

Brittleness Temp., max, deg. F (deg. C)*

ASTM D 746

-49 (-45)

-67 (-55)

Resistance to Water Absorption*
After 7 days immersion @ 70 ºC
Change in mass, max, %

ASTM D 471



+8, -2**



+2.0**

Factory Seam Strength, min

ASTM D 816
Modified

Membrane
Rupture

Membrane
Rupture

Resistance to Outdoor (Ultraviolet) Weathering* Xenon-Arc, 7560 kJ/m2 total radiant exposure at 0.70 W/m2 irradiance, 80 ºC black panel temp.


ASTM G 155
Conditions


No Cracks
No Crazing


No Cracks
No Crazing  

 

 
 

* Not a Quality Control Test due to the time required for the test or the complexity of the test. However, all tests are run on a statistical basis to ensure overall long-term performance of the sheeting.